-40%
Thermotron AST-8 / RS-16 HALT/HASS Chamber (-100°C 200°C) 58331259RF
$ 15576
- Description
- Size Guide
Description
Thermotron AST-8 / RS-16 HALT/HASS Chamber (-100°C 200°C) 58331259RFItem
Make: Thermotron
Model: AST-8 / RS-16
Options: 460, NH, W, 7800, LN2, PH2, PH8x3, GN2
Item Specifics/Condition
Refurbishment
Description
AST-8 HALT/HASS Chamber
Workspace Dimensions—WxDxH :
24 x 22 x 24 inches
Temperature Range:
-100°C to 200°C
Temperature Change Rate:
>50°C/min on product
Table Size:
18 x 18 inches
Number of Impactors:
4
Maximum Payload Capability:
300 lb
135 kg
Move-In Dimensions—WxDxH:
75 x 34 x 78 inches
Heater Size:
20 kW
Grid Pattern:
4" x 4"
Frequency Range:
0 to > 10,000 Hz
Electrical Requirements in Full Load Amps 460 / 3 / 60:
31 / 35
Electrical Requirements in Full Load Amps 400 / 3 / 50:
34 / 40
Total Compressed Air (SCFM):
90 psi
Blower:
3/4 Hp
Axes Excited:
3 linear, 3 rotational
Airflow:
370 CFM
RS-16 Vibration Table
Sampling Rate:
100 kHz / channel
Number of Impactors:
4
Load Capacity in lbs :
300 lbs
Grid Size (inches):
16 x 16 inches
Frequency Range:
0 > 20000 Hz
Compressed Air Per Impactor (SCFM):
9.5
Axes Excited:
3 linear, 3 rotational
Acceleration Level Baretable (0-10000 Hz):
50 grms
Acceleration Level (0-10000 Hz) 9B106 (5 KN export limit):
40 grms
Images
Term of sale
Included Items: