Thermotron AST-35 / RS-36 28291 HALT/HASS Chamber (-100°C to 200°C)

$ 31653.6

Availability: 100 in stock
  • Item must be returned within: 30 Days
  • Return shipping will be paid by: Buyer
  • Brand: Thermotron
  • Refund will be given as: Money Back
  • Model: Thermotron AST-35 / RS-36 28291 HALT/HASS Chamber (-100°C to 200
  • Condition: Tested Good
  • All returns accepted: Returns Accepted
  • MPN: AST-35 / RS-36

    Description

    Thermotron AST-35 / RS-36 28291 HALT/HASS Chamber (-100°C to 200°C)
    Item
    Make: Thermotron
    Model: AST-35 / RS-36
    Options: 460, NH, W, LN2, PH7x2, F4T
    Item Specifics/Condition
    Tested Good
    Description
    AST-35 HALT/HASS Chamber
    Workspace Dimensions—WxDxH :
    42 x 42 x 40 inches
    Temperature Range:
    -100°C to 200°C
    Temperature Change Rate:
    >70°C/min on product
    Table Size:
    24 x 24 inches to 36 x 36 inches
    Number of Impactors:
    consult factory
    Maximum Payload Capability:
    628 lb
    284 kg
    Move-In Dimensions—WxDxH:
    85 x 61 x 105 inches
    Heater Size:
    96 kW
    Grid Pattern:
    4" x 4"
    Frequency Range:
    0 to > 10,000 Hz
    Electrical Requirements in Full Load Amps 460 / 3 / 60:
    133 / 175
    Electrical Requirements in Full Load Amps 400 / 3 / 50:
    155 / 200
    Total Compressed Air (SCFM):
    90 psi
    Blower:
    7.5 Hp
    Axes Excited:
    3 linear, 3 rotational
    Airflow:
    4000 CFM
    RS-36 Vibration Table
    Sampling Rate:
    100 kHz / channel
    Number of Impactors:
    9
    Load Capacity in lbs :
    630 lbs
    Grid Size (inches):
    36 x 36 inches
    Frequency Range:
    0 > 10000 Hz
    Compressed Air Per Impactor (SCFM):
    9.5
    Axes Excited:
    3 linear, 3 rotational
    Acceleration Level Baretable (0-10000 Hz):
    50 grms
    Acceleration Level (0-10000 Hz) 9B106 (5 KN export limit):
    50
    Q&A
    What will be the right compressor based on the chamber size and the test required?
    The best compressor would be a "rotary screw style" air compressor. You will need at least a 1" line going from the tank to the compressor. For full capacity, you would need a 250 gallon air storage tank to assist in volume. There are some companies that make a "tankless" version, but they are very expensive.  We use an Eaton Rotary Screw Air Compressor Model PRSK070003 . It's a 7.5 HP 230 volt 3 phase. It also has a small refrigeration system built in that keeps the air dry and cool. This particular compressor comes with a 120 gallon storage tank. We added an additional 120 gallon tank for extra volume. We also use this compressor for shop/lab air and pneumatic tools. The compressor is also very quiet.
    What is the requirement for GN2 purge system since we need to run cold temperatures?
    For cold set points, you will need Ln2. You will need to contact a local Liquid Nitrogen provider. They will set you up with the correct equipment including tanks, lines, manifolds, etc...  You will also need to confirm that the chamber has been exhausted properly. Ln2 expands at a rate of 700 times and can be lethal if not properly exhausted out of the building. That chamber has an Oxygen monitor on it that will sound an alarm if it detects low levels of Oxygen.
    Gn2 purge is only required if you are trying to keep the air inside the chamber dry. This dry nitrogen, lines and tanks, etc.. can also be provided by your local gas supplier.
    What is the verified temperature and vibration limit?
    Chamber temperature range is -100c to +200c . Depending on product loading, the chamber is capable of 70 degrees c per minute. The vibration limit is 50 GRMS.
    Images
    Term of sale
    Included Items:
    This sale does not include probes, cables, manuals, power cords or any other accessories unless otherwise stated or pictured.